The CNMC has just published the electricity labelling data for energy generated in 2025, with two emission factors: 107 g/kWh as the national average for electricity generation, and another value that depends on each electricity supplier. Which one should you use to calculate your carbon footprint? The answer is: “it depends”.

In April 2026, Spain’s National Commission on Markets and Competition (CNMC) published report GDO/DE/001/26, containing the official electricity labelling data for energy generated in 2025. The document includes the labelling information for all active electricity suppliers in Spain and also establishes the 2025 national average emission factor: 107 g/kWh.

But which factor should I use to calculate my organisation’s carbon footprint: my electricity supplier’s factor or the national average?

There is no simple answer, as it depends on the calculation approach you need to follow. We explain it below.

First, what is a carbon footprint?

A carbon footprint is an environmental indicator that quantifies the total greenhouse gas (GHG) emissions released directly or indirectly as a result of an activity. It is expressed in tonnes of carbon dioxide equivalent (tCO₂e).

The most widely used standard for classifying and reporting emissions is the GHG Protocol. This framework divides emissions into three categories, known as scopes, according to where they arise within the value chain.

  • Scope 1 (direct emissions): emissions from sources directly controlled by the company, such as natural gas, petrol and so on.
  • Scope 2 (indirect energy emissions): emissions associated with generating the energy consumed by the organisation, such as electricity.
  • Scope 3 (other indirect emissions): the broadest category, covering everything that occurs outside the company’s own operations but within its value chain, including suppliers, business travel, employee commuting, waste generated and the use of sold products.

How is a corporate carbon footprint calculated?

The calculation involves measuring the level of activity at the facility and multiplying it by the emission factor, which represents the emissions produced per unit of activity.

  • Carbon footprint = Activity data × Emission factor

What are the two approaches to Scope 2?

As mentioned above, when a company consumes electricity, it generates indirect emissions that the GHG Protocol classifies as Scope 2. Since 2015, the standard has required these emissions to be calculated and reported simultaneously using two different methods.

Location-based approach

The concept is straightforward: the total CO₂e emitted from electricity generation divided by the total number of kWh generated. It represents the actual average carbon intensity of the grid, regardless of who has purchased what. Everyone connected to the same grid shares this factor in proportion to their consumption, with no special treatment.

According to the CNMC’s latest publication, the emission factor for the location-based approach in 2025 is 107 gCO₂e/kWh.

Market-based approach

This approach is based on a different premise: emissions should reflect the organisation’s contractual electricity purchasing decisions. The applicable factor depends on the contractual instruments used by your organisation:

  • Your electricity supplier’s specific factor, published by the CNMC in Annex I of the electricity labelling report. Report GDO/DE/001/26 contains values ranging from 0 gCO₂e/kWh (A rating) to more than 250 gCO₂e/kWh (G rating).
  • A zero factor, where the company has fully redeemed verified renewable Guarantees of Origin (GOs).
  • The residual-mix factor — 258 gCO₂e/kWh — for organisations with neither a specific contract nor GOs. This is what remains of the electricity mix after all renewable electricity already claimed by other consumers has been removed.

Now that we know there are two approaches, which one should be used? It depends on the purpose of the calculation.

What each regulatory framework requires

GHG Protocol – Scope 2 Guidance

It requires both methods to be reported simultaneously and separately, and this distinction corresponds directly to the two values published by the CNMC in its electricity labelling data. The location-based approach uses the actual grid average — the 107 g/kWh referred to by the CNMC as the “National average” — while the market-based approach uses the supplier’s contractual factor or, where none is available, the 258 g/kWh factor for electricity supplied without GOs. These figures are never added together: they coexist in the report and answer different questions.

ISO 14064-1

It does not prescribe a specific method, but it requires the chosen approach to be justified and reported transparently, and encourages dual reporting. Organisations certified under this standard that also report under the GHG Protocol should disclose both approaches to maintain methodological consistency across frameworks.

CSRD / ESRS

Dual reporting is required, covering both the location-based and market-based approaches. ESRS E1 explicitly states in its Appendix that companies must apply both location-based and market-based methods when calculating Scope 2 emissions, in line with the principles of the GHG Protocol Scope 2 Guidance.

Companies that were already reporting under Spain’s Non-Financial Information Statement (EINF), the legislation that the CSRD is intended to replace, are required to include information on GHG emissions. Most do so by following the GHG Protocol or using it as a methodological reference. Where the GHG Protocol is used, dual Scope 2 reporting should already be included. In practice, many Spanish companies reporting under the EINF disclose only one factor — usually the MITECO factor — without distinguishing between approaches, which is technically not compliant with the GHG Protocol.

MITECO Registry

The MITECO Carbon Footprint Registry operates de facto on an exclusively market-based basis, even though it does not describe the method in those terms. The Spanish framework was built directly around the CNMC’s electricity labelling system, which is inherently a market-tracking system, without including the actual grid average as an alternative calculation option.

This is highly significant, because organisations need to understand that figures reported to MITECO may not be valid for other reports. This is one of the most common mistakes made by organisations.

Other non-statutory requirements

In addition to regulatory obligations, many companies prepare corporate social responsibility reports or internal corporate reports, particularly multinationals. In these cases, the criterion to follow is the one defined by the organisation itself or by its parent company. It may correspond to the location-based approach, the market-based approach or a third method, such as a specific emission factor established through an internal group policy. The key is for the method to be documented and applied consistently.

What should your company do?

The starting point is not the emission factor. It is identifying which reporting frameworks apply to your organisation. Not all companies have the same obligations, and the calculation process should serve those obligations, not the other way round.
Once the relevant frameworks have been identified, the next step is to calculate the approaches required by each one. In some cases, a single factor will be sufficient; in others, both must be disclosed separately. The important thing is not to mix them or assume that one value can be used for every purpose.

Our energy consultancy can support you throughout the carbon footprint calculation process and help you meet the associated legal or internal requirements. Contact us!



Related Articles


Fore more information… 
Subscribe to our newsletter
gen0 facebook footer logogen0 instagram footer logogen0 linkedin footer logogen0 twitter footer logo
gen0 footer logo grande
Secret Link
Privacy Overview

This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.